Residual energy during machine maintenance: hydraulic, pneumatic and mechanical hazards
- Posted on
- By Ivan Marquez
- 0
This article explains what residual energy is, where it can remain and how Lockout, Tagout and Tryout (LOTOTO) practices help manage these hazards. It also introduces the principles of ISO 14118:2017, Safety of machinery — Prevention of unexpected start-up, which addresses unexpected start-up associated with external power supplies, stored energy and other influences.
When a machine is switched off, it may appear safe to inspect, clean or repair. However, switching off a machine does not necessarily eliminate all hazardous energy. Pressure can remain inside hydraulic and pneumatic systems, springs can retain mechanical tension, and raised machine components can still fall under gravity.
This remaining energy is known as residual or stored energy. If it is released unexpectedly during maintenance, it can cause uncontrolled movement, crushing injuries or other serious accidents.
Understanding where residual energy can remain, how it creates hazards and how to control it is an essential part of machine safety. A properly implemented Lockout, Tagout and Tryout (LOTOTO) procedure helps maintenance personnel isolate energy sources, control remaining hazardous energy and verify that equipment is safe before work begins.
What is residual or stored energy?
Residual or stored energy is energy that remains within a machine or its components, even after the main energy supply has been switched off or isolated.
Industrial machines use different forms of energy to perform mechanical operations. During normal operation, this energy may be transferred, converted or stored within the machine.
When the equipment stops, some of that energy may remain.
For example, a pneumatic cylinder may contain compressed air, a hydraulic accumulator may retain pressed fluid, and a spring-loaded mechanism may remain under mechanical tension.
These conditions can create hazards even though the machine is no longer operating.
The terms stored energy and residual energy are almost similar. Stored energy describes energy retained within a system or component, while residual energy commonly refers to hazardous energy remaining after shutdown or isolation.
In machine safety, the essential consideration is whether that energy could cause injury through unexpected movement or release.
Common types of residual energy

Residual energy can occur in different forms depending on the design and operation of the machine. During industrial maintenance, pneumatic, hydraulic and mechanical energy are particularly important.
Pneumatic residual energy: compressed air remaining in the system
Pneumatic systems use compressed air to operate cylinders, actuators, valves and other components.
When the compressed-air supply is shut off, pressure may remain trapped within pipework, cylinders, reservoirs or insulated sections of the pneumatic system.
A pneumatic shut-off valve does not automatically guarantee that downstream pressure has been released.
For example, closing a manually operated air supply valve may prevent additional compressed air from entering the machine. However, dependent on the valve configuration and pneumatic circuit design, air may remain trapped downstream.
Even where a valve incorporates an exhaust function, its operation does not necessarily ensure that all parts of a complex pneumatic system have been depressurized.
This remaining pressure may cause unexpected actuator movement or a sudden release of air when a component is disconnected.
The appropriate method for controlling pneumatic residual energy therefore depends on the circuit design, the installed isolation and exhaust devices, and the machine manufacturer's instructions.
Hydraulic residual energy: pressure retained after pump shutdown
Hydraulic systems use pressurized fluid to transmit force and operate equipment such as hydraulic presses, lifting mechanisms and machine actuators.
Hydraulic pressure can remain present after the pump has stopped or its electrical supply has been disconnected.
Switching off a hydraulic pump does not necessarily remove pressure from hydraulic accumulators, cylinders or insulated sections of the hydraulic system.
An accumulator, for example, is designed to store hydraulic energy. Other components, including check valves and directional control valves, may also contribute to pressure being retained within parts of a circuit.
A hydraulic system may also remain capable of producing force or unexpected movement despite the pump being switched off.
Opening a pressurized connection could result in a hazardous release of hydraulic fluid.
Hydraulic residual energy must therefore be evaluated using the machine's hydraulic documentation and manufacturer-specific maintenance and isolation instructions.
Where required, suitable measures must be used to safely control retained pressure and prevent hazard movement.
Mechanical residual energy: springs, gravity and moving components
Mechanical residual energy can remain in machine components because of compression, tension, rotation or their position.
Typical examples include compressed springs, tensioned mechanisms, elevated machine components and rotating parts that continuously moving through inertia.
Mechanical hazards may remain present even when the machine's electrical power supply has been disconnected.
For example, a compressed spring can release force when a retaining mechanism is removed. Similarly, a raised machine component may fall if the means supporting it is released or fails.
These hazards are not necessarily eliminated by disconnecting electricity or stopping a pneumatic or hydraulic drive.
Depend on the machine design, mechanical energy may need to be safely dissipated, restored or otherwise controlled using suitable protective measures.
Common examples of residual energy hazards:
| Type of energy | Example | Potential hazard |
|---|---|---|
| Pneumatic | Compressed air remains trapped downstream of a shut-off valve | Unexpected cylinder movement or sudden release of air |
| Pneumatic | Air remains inside an actuator or isolated pneumatic circuit | Movement when pressure is released or redistributed |
| Hydraulic | A hydraulic accumulator retains pressure after pump shutdown | Unexpected actuation or hazardous fluid release |
| Hydraulic | Pressure remains trapped inside a hydraulic cylinder or hose | Uncontrolled movement or release of pressurized fluid |
| Mechanical | A machine component remains raised above its resting position | Falling movement and crushing injuries |
| Mechanical | A spring remains compressed or tensioned | Sudden movement or release of stored force |
| Mechanical | A flywheel continues rotating after power disconnection | Continued hazardous movement |
Why switching off a machine is not enough
A machine may be stationary and disconnected from its main power supply while still containing potentially hazardous stored energy.
The key distinction is between stopping the machine, isolating its energy sources and controlling the energy that remains.
Stopping a machine ends its intended operation. Energy isolation prevents energy from being supplied through the relevant isolation points. However, neither action necessarily eliminates the energy already stored within the equipment.
An emergency-stop function also should not be confused with energy isolation. Emergency-stop devices are intended to initiate a stop in an emergency, whereas energy-isolating devices physically prevent the transmission or release of energy from an energy source.
The appropriate isolation and stored-energy control measures depend on the specific machine, its energy sources and the work being performed.
What does ISO 14118:2017 say about unexpected start-up?

ISO 14118:2017, Safety of machinery — Prevention of unexpected start-up, addresses measures intended to prevent unexpected machine start-up so that people can safely intervene in hazardous areas.
This covers unexpected start-up associated with different energy sources, including electrical, hydraulic and pneumatic power supplies, as well as stored energy associated with gravity and springs.
It addresses the principles of isolation, securing isolation arrangements where necessary, controlling stored energy and verifying the effectiveness of the measures taken.
However, ISO 14118:2017 does not prescribe one universal isolation solution for every machine.
The required measures must be determined with consideration of the machine's design, relevant risk assessment, applicable machine-specific safety standards and manufacturer instructions.
This distinction is particularly important for machinery containing multiple energy sources or systems in which pressure and mechanical force may remain after shutdown.
How does LOTOTO help manage residual energy risks?
Lockout, Tagout and Tryout (LOTOTO) is an approach to hazardous energy control that combines energy isolation, securing isolation points and verification before maintenance or servicing work begins.
LOTOTO helps prevent unexpected energization, machine start-up and hazardous energy release.
When residual energy is present, however, applying a lock to an isolation device is only part of the safety process.
The remaining hazardous energy must also be identified and appropriately controlled.
Identifying hazardous energy sources
The first consideration is identifying the energy sources associated with the machine.
These may include electrical supplies, pneumatic pressure, hydraulic pressure and mechanical energy stored in springs, elevated components or rotating assemblies.
The assessment must consider energy that could remain after the external supplies have been isolated.
Isolating and securing energy sources
Once the relevant energy sources have been identified, appropriate energy-isolating devices can be used in accordance with the machine-specific procedure.
Depending on the equipment, these may include electrical disconnect switches, manually operated isolation valves or other suitable isolating devices.
Lockout devices help secure applicable isolation points against unintended operation, while tags identify the isolation status and communicate that maintenance work is taking place.
The choice of isolation equipment depends on factors such as the type of energy source, the design of the isolating device and the manufacturer's instructions.
Controlling residual or stored energy
After isolation, potentially hazardous energy remaining within the machine must be appropriately controlled.
Depending on the equipment, this may involve controlled depressurization, safe dissipation of mechanical energy or the use of suitable restraints to prevent hazardous movement.
For example, residual pneumatic pressure may require a manufacturer-specified exhaust arrangement, while hydraulic systems may require particular methods for addressing retained accumulator or circuit pressure.
Elevated mechanical components may require suitable restraints or supports to prevent falling.
These are examples of possible energy-control measures rather than instructions applicable to every machine.
The correct measures must be based on the specific machine, the identified hazards and the applicable manufacturer instructions.
Where lockout equipment is relevant
Suitable lockout equipment supports the securing of energy-isolating devices during maintenance.
Depending on the installation, this may include valve lockout devices for compatible pneumatic or hydraulic isolation valves, electrical lockout devices for appropriate disconnecting equipment, and personal safety padlocks and identification tags.
However, lockout equipment does not itself guarantee that downstream pressure has been released or that mechanical stored energy has been made safe.
Its role must be understood as part of the overall hazardous energy control arrangement.
Why verification is important

Verification is essential because the presence of a lockout device or the apparent absence of machine movement does not mean that all hazardous energy has been controlled.
A machine may fail to start when its operating controls are activated while still retaining pneumatic pressure, hydraulic pressure or mechanical energy.
Verification must therefore address the effectiveness of isolation and the control of relevant residual energy hazards.
Depending on the equipment, suitable verification methods may involve checking pressure conditions at designated points, confirming the condition of mechanical restraints or using appropriate tests to establish that isolation measures have achieved their intended effect.
For example, a pneumatic circuit may require confirmation that hazardous trapped pressure has been controlled, rather than relying solely on the position of the main shut-off valve.
A hydraulic system may require verification that relevant pressurized sections have been rendered safe, even though the pump is no longer running.
For mechanical components, verification may involve confirming that suitable measures prevent unexpected movement.
The selected verification method must be appropriate to the machine and carried out in accordance with a safe working procedure.
ISO 14118:2017 addresses verification as part of isolation and energy dissipation. The principle is to establish that the protective measures have achieved their intended effect before people are exposed to the hazard.
Where stored energy can reaccumulate, additional monitoring or verification measures may be necessary during maintenance.
Conclusion: safe maintenance requires control of residual energy
Residual energy is an important consideration in machine maintenance because hazardous pressure, force or movement can remain possible after equipment has been switched off.
Pneumatic systems may retain compressed air downstream of isolation valves. Hydraulic accumulators and isolated circuit sections may remain pressurized after pump shutdown. Mechanical components such as raised machine parts and compressed springs may continue to present hazards without electrical power.
Effective LOTOTO practices help manage these risks by combining energy-source identification, appropriate isolation, securing isolation points, controlling stored energy and verification.
ISO 14118:2017 provides a framework for understanding the prevention of unexpected start-up, but the appropriate protective measures must always reflect the machine's design, risk assessment and manufacturer instructions.
The central principle is that switching off or isolating the main energy supply does not, by itself, demonstrate that a machine is safe for maintenance.
Frequently asked questions about residual energy during machine maintenance
What is residual energy in machine safety?
Residual energy is energy that remains stored within a machine or its components after the main energy supply has been switched off or isolated. Examples include compressed air in pneumatic circuits, pressure in hydraulic systems, compressed springs and raised machine parts. This energy can cause unexpected movement or hazardous releases during maintenance if it is not properly controlled.
What are the most common types of residual energy in machinery?
The most common types include pneumatic, hydraulic and mechanical energy. Pneumatic energy remains as compressed air, hydraulic energy as pressurized fluid, and mechanical energy as stored force, movement or gravitational potential energy. Machinery may contain several types simultaneously, making it important to identify all relevant energy sources before maintenance.
Can a pneumatic system remain pressurized after the air supply is switched off?
Yes. Closing a pneumatic shut-off valve does not necessarily release compressed air trapped in downstream hoses, cylinders or other parts of the circuit. Depending on the valve and system design, hazardous pressure may remain present. Appropriate pressure-control and verification measures must follow the machine manufacturer's instructions.
Can hydraulic pressure remain after the hydraulic pump is switched off?
Yes. Hydraulic accumulators, cylinders and isolated circuit sections can retain pressure even after the pump has stopped. This stored pressure may cause unexpected actuator movement or a hazardous release of hydraulic fluid. Switching off the pump must not be treated as confirmation that the entire hydraulic system has been depressurized.
What are examples of mechanical stored energy hazards?
Examples include compressed springs, tensioned mechanisms, raised machine components and rotating flywheels. A spring can release force when its restraint is removed, while a raised component may fall under gravity. These hazards can remain present even when electrical power has been disconnected.
Why is switching off a machine not enough to make maintenance safe?
Switching off a machine stops its normal operation but does not necessarily isolate all energy sources or eliminate stored energy. Pressure may remain in pneumatic and hydraulic circuits, and mechanical components may still be capable of hazardous movement. Safe maintenance requires appropriate energy isolation, control of residual energy and verification of the resulting condition.
How does LOTOTO help control residual energy hazards?
Lockout, Tagout and Tryout (LOTOTO) helps prevent unexpected energization and hazardous energy release during maintenance. It involves identifying energy sources, isolating them, securing appropriate isolation points, controlling stored energy and verifying effective isolation. The specific measures depend on the machine design, identified hazards and manufacturer instructions.
What does ISO 14118:2017 say about residual energy and unexpected start-up?
ISO 14118:2017, Safety of machinery — Prevention of unexpected start-up, addresses measures to prevent unexpected start-up, including hazards associated with electrical, hydraulic and pneumatic supplies and stored energy such as gravity and compressed springs. It provides general principles for preventing hazardous start-up but does not prescribe one universal isolation procedure for every machine.